Refrigerant Recovery Tank Valves
30lb 50lb 100lb 250lb.
Refrigerant recovery tank valves. Solid brass construction for durability and long life. The colors designate the different forms of refrigerant they recover. The below steps will vary with your recovery machine 5. Refrigerant tank 1 4 flare y valve assembly for 30 or 50 pound cylinders.
Fully open the vapor valve on the recovery. The tank s collar is designed for ease of handling. Ez one shot cylinders use dot 39 disposable cylinder technology to provide an inexpensive lightweight cylinder for use in one time fill recovery situations. Solid brass construction for durability and long life.
Refrigerant cylinders include an extra npt opening plugged for future installation of an automatic stop fill liquid level switch stackable 30lb. Up to 1000 lb. Constructed with a y valve for liquid and vapor. 3 4 npt opening accepts 80 fill with a float switch shut off device.
Start to discharge pressure. Red valve knob involves vapor the red valve is a vapor valve used to recover refrigerant in a vapor state. Cylinders and the. Relief valve for half ton portable refrigerant tanks.
Flame king s 30 pound refrigerant recovery cylinder is powder coated for high gloss and a durable finish. The recovery tank valve along with all other valves should be open the recovery machine can be turned on. Purge the hoses of air loosen and unseat the hose connected to the recovery tank until refrigerant is present and then retighten. Refrigerant cylinders store and stack efficiently and safely with any manufacturer s refrigerant recovery 30lb.
Set the recovery machine to recover. 3 4 npt port refrigerant tank 1 4 flare tank y valve assembly blue vapor red liquid. Flame king refrigerant recovery cylinder tank reusable dot compliant y valve liquid vapor 30 lb pound 4 7 out of 5 stars 328 amazon s choice for r134a recovery tank. At the hvac gauges and recovery machine you should see the pressure begin to drop as the refrigerant goes into he recovery tank.
One time fill one time fill means that once refrigerant has been put into the cylinder and then removed the cylinder may no longer be used for further recovery operations. The valve is 1 2 acme fittings for mobile applications and is ported red vapor blue liquid. 3 4 npt port v20429 manchester refrigerant tank valve assy dual port 600 psi 3 4 mpt fittings. Cylinder working pressure up to 260 psi.
The valve is 1 4 flare fittings for mobile or hvac applications and is ported red vapor blue liquid. Standard refrigerant recovery tanks come equipped with both red and blue valves located at the top of the tank. Open the high side of the manifold for liquid recovery. Vapor recovery takes more time than.
Used in conjunction with vapor and liquid recovery valve sets.